Windows PERCCLI Utility cmd as administrator cd C:\Dell\Drivers\1XC7Y\Windows perccli /c0 show =================================== to view controller details, firmware, and overall topology. perccli /c0/eall/sall show all =================================== to list every physical drive, its slot, and status. Gives you results as follows: Generating detailed summary of the adapter, it may take a while to complete. Controller = 0 Status = Success Description = None Basics : ====== Controller = 0 Model = PERC H310 Adapter Serial Number = 48S00RZ Current Controller Date/Time = 07/14/2026, 19:04:06 Current System Date/time = 07/14/2026, 19:04:06 SAS Address = 5b083fe0ca69fd00 PCI Address = 00:08:00:00 Mfg Date = 09/01/14 Rework Date = 09/01/14 Revision No = A06 Version : ======= Firmware Package Build = 20.12.1-0002 Firmware Version = 2.120.14-2657 Bios Version = 4.34.00_4.12.05.00_0x05260000 Preboot CLI Version = 03.02-015:#%00008 Ctrl-R Version = 3.00-0022 NVDATA Version = 3.09.03-0038 Boot Block Version = 2.02.00.00-0001 Driver Name = percsas2.sys Driver Version = 6.802.19.00 Bus : === Vendor Id = 0x1000 Device Id = 0x73 SubVendor Id = 0x1028 SubDevice Id = 0x1F4E Host Interface = PCI-E Device Interface = SAS-6G Bus Number = 8 Device Number = 0 Function Number = 0 Pending Images in Flash : ======================= Image name = No pending images Status : ====== Controller Status = Needs Attention Memory Correctable Errors = 0 Memory Uncorrectable Errors = 0 ECC Bucket Count = 0 Any Offline VD Cache Preserved = No BBU Status = NA PD Firmware Download in progress = No Lock Key Assigned = No Failed to get lock key on bootup = No Lock key has not been backed up = No Bios was not detected during boot = No Controller must be rebooted to complete security operation = No A rollback operation is in progress = No At least one PFK exists in NVRAM = No SSC Policy is WB = No Controller has booted into safe mode = No Supported Adapter Operations : ============================ Rebuild Rate = Yes CC Rate = Yes BGI Rate = Yes Reconstruct Rate = Yes Patrol Read Rate = Yes Alarm Control = Yes Cluster Support = No BBU = No Spanning = Yes Dedicated Hot Spare = Yes Revertible Hot Spares = Yes Foreign Config Import = Yes Self Diagnostic = Yes Allow Mixed Redundancy on Array = No Global Hot Spares = Yes Deny SCSI Passthrough = No Deny SMP Passthrough = No Deny STP Passthrough = No Support more than 8 Phys = Yes FW and Event Time in GMT = No Support Enhanced Foreign Import = Yes Support Enclosure Enumeration = Yes Support Allowed Operations = Yes Abort CC on Error = Yes Support Multipath = Yes Support Odd & Even Drive count in RAID1E = No Support Security = No Support Config Page Model = Yes Support the OCE without adding drives = Yes Support EKM = No Snapshot Enabled = No Support PFK = No Support PI = No Support Ld BBM Info = No Support Shield State = No Block SSD Write Disk Cache Change = No Support Suspend Resume BG ops = No Support Emergency Spares = No Support Set Link Speed = No Support Boot Time PFK Change = No Support JBOD = No Disable Online PFK Change = No Support Perf Tuning = No Support SSD PatrolRead = No Real Time Scheduler = No Support Reset Now = No Support Emulated Drives = No Headless Mode = No Dedicated HotSpares Limited = No Point In Time Progress = No Extended LD = No Boot Volume Supported = No Support Uneven span = No Support Config Auto Balance = No Support Maintenance Mode = No Support Diagnostic results = No Support Ext Enclosure = No Support Sesmonitoring = No Support SecurityonJBOD = No Support ForceFlash = No Support DisableImmediateIO = No Support LargeIOSupport = No Support DrvActivityLEDSetting = No Support FlushWriteVerify = No Support CPLDUpdate = No Support ForceTo512e = No Support discardCacheDuringLDDelete = No Support JBOD Write cache = No Support Large QD Support = No Support Ctrl Info Extended = No Support IButton less = No Support AES Encryption Algorithm = No Support Encrypted MFC = No Supported PD Operations : ======================= Force Online = Yes Force Offline = Yes Force Rebuild = Yes Deny Force Failed = No Deny Force Good/Bad = No Deny Missing Replace = No Deny Clear = Yes Deny Locate = No Support Power State = Yes Set Power State For Cfg = No Support T10 Power State = Yes Support Temperature = Yes NCQ = No Support Max Rate SATA = No Supported VD Operations : ======================= Read Policy = No Write Policy = No IO Policy = No Access Policy = Yes Disk Cache Policy = Yes Reconstruction = Yes Deny Locate = No Deny CC = No Allow Ctrl Encryption = No Enable LDBBM = Yes Support FastPath = Yes Performance Metrics = Yes Power Savings = Yes Support Powersave Max With Cache = No Support Breakmirror = Yes Support SSC WriteBack = No Support SSC Association = No Support VD Hide = No Support VD Cachebypass = No Support VD discardCacheDuringLDDelete = No HwCfg : ===== ChipRevision = B2 BatteryFRU = N/A Front End Port Count = 0 Backend Port Count = 8 BBU = Absent Alarm = Missing Serial Debugger = Present NVRAM Size = 32KB Flash Size = 16MB On Board Memory Size = 0MB CacheVault Flash Size = NA TPM = Absent Upgrade Key = Absent On Board Expander = Absent Temperature Sensor for ROC = Present Temperature Sensor for Controller = Present Upgradable CPLD = Absent Current Size of CacheCade (GB) = 0 Current Size of FW Cache (MB) = 0 ROC temperature(Degree Celsius) = 59 Ctrl temperature(Degree Celsius) = 47 Policies : ======== Policies Table : ============== ------------------------------------------------ Policy Current Default ------------------------------------------------ Predictive Fail Poll Interval 300 sec Interrupt Throttle Active Count 16 Interrupt Throttle Completion 50 us Rebuild Rate 30 % 30% PR Rate 30 % 30% BGI Rate 30 % 30% Check Consistency Rate 30 % 30% Reconstruction Rate 30 % 30% Cache Flush Interval 4s ------------------------------------------------ Flush Time(Default) = 4s Drive Coercion Mode = 128MB Auto Rebuild = On Battery Warning = Off ECC Bucket Size = 15 ECC Bucket Leak Rate (hrs) = 24 Restore HotSpare on Insertion = Off Expose Enclosure Devices = Off Maintain PD Fail History = Off Reorder Host Requests = On Auto detect BackPlane = SGPIO/i2c SEP Load Balance Mode = Auto Security Key Assigned = Off Disable Online Controller Reset = Off Use drive activity for locate = Off Boot : ==== BIOS Enumerate VDs = 1 Stop BIOS on Error = On Delay during POST = 0 Spin Down Mode = None Enable Ctrl-R = Yes Enable Web BIOS = No Enable PreBoot CLI = No Enable BIOS = Yes Max Drives to Spinup at One Time = 4 Maximum number of direct attached drives to spin up in 1 min = 20 Delay Among Spinup Groups (sec) = 12 Allow Boot with Preserved Cache = Off High Availability : ================= Topology Type = None Cluster Permitted = No Cluster Active = No Defaults : ======== Phy Polarity = 0 Phy PolaritySplit = 0 Strip Size = 64 KB Write Policy = WT Read Policy = No Read Ahead Cache When BBU Bad = Off Cached IO = Off VD PowerSave Policy = Controller Defined Default spin down time (mins) = 30 Coercion Mode = 128 MB ZCR Config = Unknown Max Chained Enclosures = 4 Direct PD Mapping = Yes Restore Hot Spare on Insertion = No Expose Enclosure Devices = No Maintain PD Fail History = No Zero Based Enclosure Enumeration = Yes Disable Puncturing = No EnableLDBBM = Yes DisableHII = No Un-Certified Hard Disk Drives = Allow SMART Mode = Mode 6 Enable LED Header = No LED Show Drive Activity = Yes Dirty LED Shows Drive Activity = No EnableCrashDump = No Disable Online Controller Reset = No Treat Single span R1E as R10 = Yes Power Saving option = Enabled TTY Log In Flash = Yes Auto Enhanced Import = No BreakMirror RAID Support = Yes Disable Join Mirror = Yes Enable Shield State = No Time taken to detect CME = 60 sec Capabilities : ============ Supported Drives = SAS, SATA Boot Volume Supported = NO RAID Level Supported = RAID0, RAID1, RAID5, RAID00, RAID10, RAID50 , PRL 11, PRL 11 with spanningPRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Enable JBOD = Yes Mix in Enclosure = Allowed Mix of SAS/SATA of HDD type in VD = Not Allowed Mix of SAS/SATA of SSD type in VD = Not Allowed Mix of SSD/HDD in VD = Not Allowed SAS Disable = No Max Arms Per VD = 16 Max Spans Per VD = 8 Max Arrays = 16 Max VD per array = 16 Max Number of VDs = 16 Max Parallel Commands = 31 Max SGE Count = 60 Max Data Transfer Size = 8192 sectors Max Strips PerIO = 20 Max Configurable CacheCade Size(GB) = 0 Max Transportable VDs = 0 Min Strip Size = 64 KB Max Strip Size = 64 KB Scheduled Tasks : =============== Consistency Check Reoccurrence = 168 hrs Next Consistency check launch = NA Patrol Read Reoccurrence = 168 hrs Next Patrol Read launch = 07/18/2026, 04:00:00 Battery learn Reoccurrence = NA OEMID = Dell Drive Groups = 2 TOPOLOGY : ======== ---------------------------------------------------------------------------- DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR ---------------------------------------------------------------------------- 0 - - - - RAID1 Optl N 465.25 GB dflt N N dflt N N 0 0 - - - RAID1 Optl N 465.25 GB dflt N N dflt N N 0 0 0 :0 0 DRIVE Onln N 465.25 GB dflt N N dflt - N 0 0 1 :1 1 DRIVE Onln N 465.25 GB dflt N N dflt - N 1 - - - - RAID1 Dgrd N 931.0 GB dflt N N dflt N N 1 0 - - - RAID1 Dgrd N 931.0 GB dflt N N dflt N N 1 0 0 :2 2 DRIVE Rbld Y 931.0 GB dflt N N dflt - N 1 0 1 :3 3 DRIVE Onln N 931.0 GB dflt N N dflt - N ---------------------------------------------------------------------------- DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present TR=Transport Ready Virtual Drives = 2 VD LIST : ======= -------------------------------------------------------------- DG/VD TYPE State Access Consist Cache Cac sCC Size Name -------------------------------------------------------------- 0/0 RAID1 Optl RW Yes NRWTD - OFF 465.25 GB SYS 1/1 RAID1 Dgrd RW Yes NRWTD - OFF 931.0 GB DATA -------------------------------------------------------------- Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked| Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack| FWB=Force WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency Physical Drives = 4 PD LIST : ======= -------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp -------------------------------------------------------------------------- :0 0 Onln 0 465.25 GB SATA HDD N N 512B ST500NM0003-9ZM172 U :1 1 Onln 0 465.25 GB SATA HDD N N 512B ST500NM0003-9ZM172 U :2 2 Rbld 1 931.0 GB SATA HDD N N 512B TOSHIBA MG03ACA100 U :3 3 Onln 1 931.0 GB SATA HDD N N 512B TOSHIBA MG03ACA100 U -------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded